Electrical Design
Organization Scheme of Electrical Engineering Department
Tender Team
- Interpreting customer specifications
- Preparing optimum designs as per customer request and necessary standards. Types of power transformer given by tender team are up to the 525 kV voltage level(525 kV included):
- Network Transformer
- Generator Transformer
- Autotransformers
- Shunt Reactors
- Electrical Arc Furnace Transformers
- Ladle Furnace Transformers
- Serial Reactors
- In case of predimensional drawing send of design sheet to mechanical design department.
- In case of customer design request consulting to R & D department.
Electrical Design Team
- Interpreting customer specifications.
- Preparing the final design by making the electrical design calculations below.
- Core type, dimensions determination and calculation of thermal heating and voltage of core.
- Insulation level, winding type, copper type, copper dimensions determination.
- Winding heating calculation.
- Impedance calculation.
- Short circuit endurance calculation.
- Impulse test endurance check.
- Selection of bushing, tap changer and to place the order of critical materials like bushing, tap changer and copper.
- Selection of monitoring device as per customer request and to place order.
Winding Design Team
- Design of insulation type as per design document.
- Preparing the winding drawings and sending to the winding manufacturing department.
- To place order of insulation materials.
|